EM 300 PD-6 Erengy Quality Analyzer
Product description:
●ModBUS-RTU, suitable for SCADA,PLC and such software● 96*96*84mm big LCD
● Three phase all parameters measurement
● Penergy measurement, max./min value statistics, multi-tariff statistics, 12 months energy data recording
Viewed:301
- Overview
- Function
- Specification
- Download
1. 96*96*84mm big LCD
2. Three phase all parameters measurement
3. Active/reactive power energy measurement, max./min value statistics, multi-tariff statistics, 12 time interval,4 time tariffs, division multi-tariff energy timing recording,12 months energy data recording
4. V/Amp 2~63 THD, V/Amp zero-sequence component, V/Amp unbalance degree, Voltage peak factor, THF, current K coefficient, current percentage compositions, voltage flicker
5. Data recording: SOE record, fault waving
6. ModBUS-RTU, suitable for SCADA,PLC and such software
7. Support logo customization
Optional:
1. DI: 6 or 8 channels
2. DO: 2 or 3 channels
3. AO: 1 channel 4~20mA output
4. 2 channel RS 485
5. Leakage monitoring
DETAILS |
|||
Input
Test
Display
|
Web |
3P3L,3P4L Configuration |
|
Voltage |
Rated value |
AC100V or AC57.7 V Optional |
|
Overload |
Measurement:1.2 times, Instantaneous 2 times/1s |
||
Consumption |
<1VA per phase |
||
Impedance |
>400kΩ |
||
Precision |
RMS measurement Precision ±0.2% |
||
Current |
Rated value |
AC5A or AC1A |
|
Overload |
Continued 1.2 times Instantaneous 10 times/5s |
||
Consumption |
<0.4VA per phase |
||
Impedance |
<20mΩ |
||
Precision |
RMS measurement Precision ±0.2% |
||
Frequency |
40~60Hz Precision ±0.02Hz |
||
Display |
LCD display Modbus communication to change the display interface |
||
Power |
Active/reactive power, apparent power, accuracy +/-0.5% |
||
Energy |
Total absolute value active/reactive, input absolute value energy active/reactive, output absolute value energy active/reactive |
||
Energy impulse |
2 channels |
||
Harmonic |
THDV+/-0.5%;Current THD +/-0.5% |
||
Clock |
<0.5s/d |
||
Leak monitoring |
Input range:0000Ma,a;alarming value:30~1000Ma,adjust steps 1mA |
||
Digital input |
Input |
Opto-isolator, Passive idle contact input |
|
Isolation Voltage |
2500Vrms |
||
Digital output |
Output |
Mechanical contact(passive) |
|
Voltage |
Max.:AC250V DC30V |
||
Current |
Max.:5A |
||
Communication |
Interface |
RS485 |
|
Protocol |
ModBUS-RTU |
||
Baud rate |
2400~9600bps Default 9600bps |
||
Working power |
Working voltage |
AC:85V~265V or DC:100V~360V |
|
Power consumption |
≤2VA |
||
Work environment |
Work temperature |
-20℃~55℃ |
|
Storage temperature |
-40℃~85℃ |
||
Humidity |
0~93% non-condensate |
||
Safe |
Insulating strength |
Isolation resistance:>100 MΩ Withstand voltage: 2kV 1 min. |